- Home
- ยป
- Our Products
- »
- GFE
GFE
Valkyrie AS Addressable Sounder Strobe Beacon
Product Brochure
Usage/Application | Offices |
Material | ABS |
Body Material | Plastic |
Color | Red |
Model Name/Number | Valkyrie AS |
We are engaged in offering Valkyrie AS Addressable Sounder Strobe Beacon to our clients. Our range of all products is widely appreciated by our clients.
Addressable Wall Mounted Sounder.
Single loop Addressable Fire Alarm Panel
Product Brochure
Usage/Application | Commercial |
Body Material | Plastic |
Product Type | Addressable Fire Alarm Panel |
Brand | GFE |
Model Name/Number | G-One |
Color | White (RAL 9003) or Red (RAL 3001) |
Single Loop EN54 Fire Alarm Control Panel
Global Fire GFE-SWR-IR3 Ex-Proof 3 Sensors IR Flame Detector
Product Brochure
Color | Red and White |
Model Name/Number | GFE-SWR-IR3 |
Brand | Global Fire |
Current In Alarm (24 V Dc) | +/- 75 mA at 24 VDC |
Cable Gland | M20 (cable conduit diameter 5.5-13 mm, two steps 5.5-8 mm and 8-13 mm) |
Alarm Output Setting | Selectable LEDs And Relays Latching/Non Latching |
Current Normal | 25 mA at 24 VDC |
(Optional) GFE-SWR-BKT Weight | 280 g |
Weight | 465 g |
Alarm Response Time | < 8 sec |
(Optional) GFE-SWR-BKT Materia | PA66, 316SS nuts and bolts |
Power | 12-24 Vdc (10-28 VDC) |
Automatic And Manual Self Test | Automatic Sensor Test (Built in Self-Test) and manual self-test |
Pressure Compensating Element | PCE (Pressure Compensating Element) avoids moisture build up in the detector housing, caused by pres |
Relay Outputs/Alarm Relay | De-energized during normal operation, no alarm, SPDT, 30 Vdc - 2 A, 60 W max. |
Relay Output/Fault Relay | Energized during normal operation, no fault, SPDT, 30 Vdc - 2 A, 60 W max. |
Ingress Protection | IP65 |
Current Output | Standard available 0-20 mA (stepped, sinking, non-isolated) |
Cone Of Vision | 90 minimum |
Startup Time | <10 sec |
Detection Range | GFE-SWR-UV & GFE-SWR-UVIR: 17 m (n-heptane; 33x33 cm); 25m (alcohol; 50x50 cm) GFE-SWR-IR3: 35 m (n- |
Housing | Glass Reinforced Polyester (GRP), Lid screw tightening torque 2 nm minimum |
Dimensions | 125 x 80 x 57 mm |
GFE announces the addition of flame detectors to our range, providing an additional high quality and competitive solution to our customers.
This new range has 3 models covering UV and IR wavelengths, namely UV, triple IR and combined UV/IR detection. With CPR and ATEX certification it will be a good option for the majority of scenarios here flame detection technology is required.
GFE-SWR-IR3 flame detector must exceed its alarm threshold to initiate a fire alarm. The GFE-SWR-IR3 flamedetector also use additional alarm criterion: the analysis of the flame flicker-frequency. This version also exhibits good false alarm rejection capabilities.
GFE-SWR Flame Detectors GFE-SWR flame detector range utilizes a microprocessor for sophisticated electronic signal analysis. Its advanced discrimination technology and rugged construction makes it suitable for almost all installations scenarios as it's presented in application table below. GFE-SWR-UVflame detector is suitable for indoor applications, such as fume hoods and hydrogen storages. Because of its non-corrosive housing it is suitable for indoor industrial areas where corrosion may occur. UV light is emitted in practically every fire, both hydrocarbon and non-hydrocarbon fires. GFE-SWR-UVIR flame detector is a combination of UV and IR detections, it uses an additional alarm criterion: the analysis of the flame flicker frequency. The UV and IR sensor must both exceed their alarm threshold to initiate a fire alarm. The GFE-SWR-UVIR flame detector has a good false alarms immunity since the UV and IR sensor do not share false alarm sources. GFE-SWR-IR3 flame detector must exceed its alarm threshold to initiate a fire alarm. The GFE-SWR-IR3 flame detector also use additional alarm criterion: the analysis of the flame flicker-frequency. This version also exhibits good false alarm rejection capabilities.
Key Features:
- Suitable for heavy and light Hydrocarbons such as Gasoline, Diesel, Methanol and Ethanol
- Resistant to artificial and sunlight
- Suitable for indoor and outdoor applications
- GRP IP65 housing
- Relay output for Alarm and Fault conditions
- CPR/EN54-10 certified
- ATEX zone 2/22 certified
- FM3260 & 3611 Approvals
- Rugged sensors make the detector suitable for virtually all fire types
- Sophisticated software enhances the reliability and availability of the detector
- Design of the housing and the swivel mount avoid mounting errors with regards to grounding
- Automatic Sensor Test (Built-in Self-Test) enhances the reliability and availability of the flame detector
- Pressure Compensating Element avoids additional cost of maintenance caused by moisture build up and increases the life time.
Addressable Manual Call Point
Product Brochure
Material | ABS Plastic |
Usage/Application | Fire Alarm System |
Model Name/Number | GFE-MCPE-A |
Dimensions Mm | Surface Mounted 92.6 (H) x 92.6 (W) x 60.1 (D) mm |
Relay Outputs | Alarm Relay |
Color | Red |
Weight | 152g Includes back box and fixings |
Conventional Heat Detector
Product Brochure
Startup Time (sec) | 10 sec |
Operating Temperature | -10 DegreeC to 50 DegreeC |
System Components | Heat detector |
Type | Conventional |
Model Name/Number | ZEOS-C-H |
Automation Grade | Automatic |
Color | White |
Body Material | Plastic |
- Heat detectors generally detect the heat that comes as a result of combustion.
- The devices trigger an alarm when they sense a rapid rise in temperature or when a certain temperature is reached.
Features:
Heat detectors are vital devices for detecting fires and ensuring safety.
As the name suggests, the devices sense the temperature of a room or area in order to detect fires.
Heat detectors work on a similar principle used by smoke detectors, by tracking the temperature instead of smoke.
Get the best price for Fire Alarm Heat Detector
Conventional Smoke Detector.
Product Brochure
Alarm Sensor Type | Photoelectric |
Brand | GFE |
Usage/Application | Industrial |
Product Type | Conventional |
Power Source | Electric |
Color | White |
Automation Grade | Automatic |
Voltage | 10-30 V DC |
TheZEOS-CseriesofFireAlarmDetectorshasbeendesignedtobeexclusivelycompatiblewiththeGlobalFireEquipment range of conventional detection zones available in the following equipment Conventional Panels: ORION, ORION MINI, ORION EX and ORION-PLUS Addressable Zone Monitoring Units: QUAD-ZMU and ZM U
Get best price for Photoelectric GFE_ZEOS-C-S, For Industrial
3 Loop Addressable Fire Alarm Panel
Product Brochure
Usage/Application | Industrial |
Product Type | Addressable Fire Alarm Panel |
Brand | GFE |
Model Name/Number | Octo + 3 Loop |
Power | 90V AC to 230V AC |
Color | White (RAL 9003) or Red (RAL 3001) |
Additional Information:
- Delivery Time: 3-4 weeks
Two Loop Addressable Fire Alarm Panel
Product Brochure
Usage/Application | Industrial |
Type | Automatic |
Brand | GFE |
System Components | Fire Alarm Control Panel |
Model Name/Number | GEKKO-2L |
Color | White |
Analogue Addressable Control Panel
Analogue Addressable Control Panel
Product Brochure
Product Type | Addressable Fire Alarm Panel |
Brand | GFE |
Model Name/Number | GEKKO 2L |
Weight | 1.6 Kg - 7 Kg |
Stand By Batteries | 2 x 12 V 7 AH |
Loops | 1 to 4 loops - Max 150 mA per loop |
Color | Red |
- 1 to 4 loops panel networkable panel, compatible with OCTO+ and NODE+ range of panels.
- Supports connection to Repeaters via RS422, Fibre-Optic or TCP/IP 250 devices per loop (125 address limit Up to 95 VULCAN 2 (addressable) ultra low current base sounders (32 address limit 32 individually programmable sounder addresses.
- Full Self-Addressable devices support 2 Fire output relays (change-over) and 1 fault relay (NC - opens on fault 2 conventional alarm outputs (individually programmable oth detection loops monitored for integrity 384 fully programmable zones 512 fully programmable sounder groups 512 I/O groups.
- Event log (rolling, 10000 entries available only with ZEOS protocol compatible with all our own low cost ancillary modules.
- Backlit graphical LCD display of 240x64 pixels programming by integrated keypad or loader PC software multiple language support (menu selectable Integrated 16 zone LED fire zone indication)
Orion Extinguishing Panel
Product Brochure
Brand | Orion |
Weight | 1.7 Kg - 7 Kg (inc. 2 x 7 AH 12 V bat.) |
Zone Current Quiescent/ Alarm | 4 mA / 60 mA - Maximum |
Protection | IP30 |
Voltage Output | 27.5 V DC Nominal |
BS5839 Detector Removal Compliant | YES provided diodes are fitted to detector base |
Dimensions | 273 (L) x 107 (W) x 404 (H) mm |
Current Output | 1000 mA combined maximum current drive for both circuits |
Colour | White or Red |
Model No. | ORION EX |
Secondary Supply Current Output | 1.85 Amp Maximum @ 20 C |
Alarm Resistance Value | 270 - 1000 Ohms |
Primary Supply Voltage Out | 28.5 V DC Nominal |
Internal Battery Capacity Maximum | 2 x 12V x 7Ah Sealed VRLA Lead Acid Batteries |
Relay Contact Rating | 30 V DC - 2 Amp Resistive Loads |
Number Of Detection Zones | 3 |
End Of Line Resistor | 10 K Ohms - 1/4 Watt |
Primary Supply Voltage | 230 +10% -15% V AC |
Mains Fuse | 4 A -250 V Slow Blow - 20mm |
Battery Fuse | 1.85 Amp - Resettable |
Secondary Supply Voltage | 21.0 min. - 27.2 max. V DC - BAT Charger o/p 28 V DC |
Devices Per Zone | 32 Maximum - EN54 pt.2 |
Fully Monitored Inputs | Remote Activation, Remote Abort, Electrovalve Status, Flow/Pressure Switch Status |
End Of Line Monitoring | Active EOL - 10uF/50V Bipolar Electrolytic Aluminium Capacitor |
Primary Supply Current Out | 1.7 A @ 28.5 V DC Nominal (max.) |
Auxiliary Relay Output | 1 Fire (COM-NC-NO) - 1 Fault (COM-NC) non-supervised |
Max Humidity | 95% RH Non-Condensing |
Evacuation And Reset | Non-Latching - Voltage free contact |
Max Cable Resistance Capacitance | 40 Ohms / 0.470 uF |
- 3 fire detection zones, with zones 1 and 2 linked with extinguishing cycle
- Up to 32 conventional smoke and/or heat detectors per zone
- Active end of Line monitoring (10uF/50V bipolar capacitor) for zones
- Programmable pre-release and extinguishing times
- Remote manual activation and remote abort input
- Electro valve and pressure switch status indication
- One man test
- Supervised auxiliary 24 volt supply output
- 2 Supervised/monitored output circuits
- 2 Remote inputs used for activation of evacuation and Reset
- 2 Relay outputs fire and fault with status indication
- Fully EN 54-2, EN54-4 and EN 12094-1 complian it
Orion Ex conventional fire detection & extinguishing panel the Orion Ex conventional fire detection and extinguishing panel offers a creatively designed and aesthetically pleasing solution to satisfy the growing world demand for dependable fire suppression systems. The Orion Ex is designed and manufactured to comply with EN54-2, EN54-4 and EN12094
1. The outstanding programmable features included in this panel are best suited to be installed in expensive housing areas and in general in all areas where loss of equipment can partially or totally disrupt the proper functioning of a business.
2. Operation is extremely intuitive, offering simple control and one-button disablement facilities, as well as the one man test mode which provides simple and efficient testing of the system.
3. Advanced configuration solutions include the following: programmable pre-release and extinguishing times, electrovalve and flow switch status indications, manual and abort remote activation.
4. There are 3 normal fire detection zones.
5. All inputs are fully monitored for both fire, activation and fault conditions.
6. Plans are under way to further complement this new range of extinguishing devices.
7. Devices such as repeater panels, addressable system interfaces, I/O expansion boards as well as manual/abort call buttons for remote connection are just some of the additions to this range.
Conventional Smoke Detector
Product Brochure
Material | ABS Plastic |
Operating Voltage | 10 V to 33 V DC |
Operating Current | Less than 50 Micro A @ 24V |
Operating Temperature | -10 DegreeC to 55 DegreeC |
Relative Humidity | 93% RH Non-Condensing |
Brand/Company | GFE |
Dimension | 93.5 mm (D) x 46.2 mm (H) inc. base |
Weight | 87g inc. base |
Certification | CE |